Unisex Changing Rooms: Sizes, Layouts and How Many a Club Needs
Guide
A unisex changing room is a fully enclosed, lockable space used by one person, or one family or player and assistant, at a time. A single changing cubicle starts at 1000mm x 1100mm, a self-contained cubicle with its own shower needs roughly 2000mm x 1000mm of shower space on top, and the door needs at least 650mm clear width with 465mm of manoeuvring space clear of the door swing. Sport England calls these all-gender facilities rather than unisex, and that wording matters when you are reading the guidance. This page sets out the sizes, how many cubicles a club realistically needs, and what it does to the footprint of a building, drawing on Sport England’s Accessible and Inclusive Sports Facilities guidance (Part D, 2024) and the standards collected in our changing room dimensions guide.
What Is a Unisex Changing Room?
In everyday club language, unisex means anyone can use it. In facility guidance it means something more specific: a space that is private enough that gender does not come into it, because only one party is inside and the door locks. Sport England’s Part D guidance sets out the arrangement types clubs will meet, and they are worth knowing by name before you brief a designer.
| Arrangement | What It Means |
|---|---|
| Open changing | Bench changing in a room allocated to one group at a time. The standard two team pavilion layout. |
| Private changing cubicle | An enclosed cubicle for one person, or a person with an assistant, placed inside a larger changing room. |
| Self-contained changing room | A private room entered from a corridor rather than from inside a changing room. Can include a shower, or a shower and WC. |
| Changing village | A matrix of private cubicles around shared locker clusters. Usual in pools, rare in club buildings. |
| Buffer changing | A room between two changing rooms that can be joined to either as group sizes change. |
What most clubs mean when they ask us for a unisex changing room is the third one: a self-contained room off the corridor, with a lockable door, a bench and in most cases a shower. Sport England notes that these rooms also do duty for officials, umpires, coaches and staff, which is usually the argument that gets them into the budget.
What Size Is a Unisex Changing Cubicle?
The figures below are the ones that decide whether a layout works. They come from Part D and from the standards in our dimensions guide.
| Element | Size |
|---|---|
| Single changing cubicle | 1000mm x 1100mm minimum |
| Two person cubicle | 1500mm x 1100mm minimum |
| Standard shower cubicle | 1000mm wide x 2000mm deep |
| Cubicle door clear width | 650mm minimum standard, 700mm minimum for ambulant accessible, 750mm preferred |
| Manoeuvring space clear of the door swing | 465mm minimum, 500mm preferred; 765mm minimum for ambulant accessible |
| Changing bench | 450mm deep, cantilevered, set 480mm above floor level |
| Clothes hooks | Two, at 1050mm and 1400mm above floor level |
| Lighting | 100 lux minimum at floor level, 150 lux minimum at bench level |
Two details catch people out. The first is that cubicle sizes in the guidance are written for panel partition systems, so a room built in solid construction needs its internal size adjusted upward to keep the same manoeuvring space. The second is that a private room entered off a corridor needs full height solid wall and door construction to its perimeter, not partitioning. A 1000mm wide cubicle panel system is not the same product as a 1000mm wide room.
How Much Circulation Space Does It Need?
Cubicles are easy to draw and easy to under-space. The circulation in front of them is what makes a layout usable with kit bags and wet floors.
| Space | Requirement |
|---|---|
| Circulation to the face of cubicles, benching or locker doors | 1500mm minimum clear width |
| Passing places | 1800mm, available within around 5m of any location |
| Clear width at wall openings and constrictions | 1000mm minimum, 1200mm to 1500mm preferred |
On a modular building that is the figure that decides the width of the unit. A 2435mm wide cabin with 1000mm cubicles down one side leaves you roughly 1400mm of corridor before wall build-up, which is why our unisex shower plans run cubicles down one side only rather than facing each other.
How Many Unisex Cubicles Does a Club Need?
There is no ratio in the guidance that converts players into cubicles, because it depends on how the building is programmed. In practice we size it from the turnover, not the headcount. A club whose Sunday runs back to back fixtures needs cubicles sized for the gap between games, not for the squad. The questions worth answering before you decide are these.
| Question | Why It Changes The Answer |
|---|---|
| How many fixtures run back to back? | Two teams arriving while two are showering is the real peak, not the squad size. |
| Do you host officials and visiting coaches? | A self-contained room doubles as the officials room and removes a whole separate space from the plan. |
| Is the ground used by juniors and adults on the same day? | Mixed age use is the most common reason clubs add private cubicles. |
| Who else uses the building midweek? | Community hire usually needs a lockable room with a WC rather than a team room. |
From the clubs we have supplied, the common landing point for a single pitch site is two to four self-contained rooms alongside the team changing, with one of them sized for accessible use. That is enough to cover officials, mixed age sessions and anyone who would otherwise not get changed at all, without paying for a cubicle per player.
What Does the Guidance Say About All Gender Provision?
Two separate things sit behind this question and it helps to keep them apart. The design standards are in Sport England’s Part D guidance, which uses the term all-gender and sets out the sizes above. The legal position on single-sex services is covered by the Equality and Human Rights Commission’s statutory Code of Practice for services, public functions and associations, which came into force on 5 August 2026 following the Supreme Court judgment of April 2025.
We design and build to the provision a club decides on. We are not the right people to tell you what that provision should be. Check the current EHRC Code of Practice and your national governing body’s guidance, and take your own advice before you settle a policy. What we can say from the plans that cross our desk is that lockable self-contained rooms are the provision that answers the widest range of questions at once, which is why they keep appearing on layouts that started out as two team buildings.
What Size Building Does Unisex Changing Need?
Here is what the figures turn into on real modular plans. Every size below is an external footprint from our own floor plans, and every plan can be adjusted.
| Plan | Size and Use |
|---|---|
| SCR49 | 2989mm x 2435mm. One shower, changing space for three to four people. The smallest standalone unit that works. |
| SCR43 | 6055mm x 2435mm. Four unisex shower cubicles with basins. |
| SCR39 | 9120mm x 2435mm. Six unisex shower cubicles, suited to a ground running back to back fixtures. |
| SCR44 | 4885mm x 2435mm. Unisex changing with toilet and shower, laid out for disabled access. |
Sizes and guide prices for each plan are on the plan pages, and the full set is on our floor plans page. Accessible provision has its own set of figures, covered in how big an accessible changing room needs to be.
When Does Unisex Changing Work Better Than Separate Rooms?
Not always, and the honest answer is that it depends on what the building is for. Separate team rooms are still the right call for a club whose use is two senior teams and a referee, because open bench changing moves a squad through faster than any number of cubicles and costs less per player. Private rooms earn their place when the user list is mixed: juniors and adults on the same afternoon, women’s and men’s sections sharing one pitch, officials with nowhere to go, disabled players, and community hire midweek.
The pattern we see most often is not a choice between the two. It is a two team building with two or three self-contained rooms added along the corridor, which is also the cheapest way to make a single building serve a club that has outgrown its original user list.
Frequently Asked Questions
What Size Is a Unisex Changing Cubicle?
A single person changing cubicle is 1000mm x 1100mm minimum and a two person cubicle is 1500mm x 1100mm minimum. The door needs at least 650mm clear width, with 465mm minimum manoeuvring space clear of the door swing, rising to 700mm and 765mm for an ambulant accessible cubicle. Those sizes are for panel partition cubicles, so a room in solid construction needs to be slightly larger internally.
What Is the Difference Between a Unisex and an All Gender Changing Room?
Nothing in practice. All-gender is the term Sport England uses in its Accessible and Inclusive Sports Facilities guidance, and unisex is what most clubs and suppliers say. If you are reading the guidance and cannot find the word unisex, that is why.
How Big Is a Unisex Shower Cubicle?
A standard shower cubicle is 1000mm wide by 2000mm deep. Add the changing space in front of it if the cubicle is self-contained rather than opening onto a shared drying area.
How Many Unisex Changing Rooms Does a Sports Club Need?
There is no fixed ratio. Size it from how many teams are in the building at once rather than from squad numbers. Most single pitch clubs we supply settle on two to four self-contained rooms alongside the team changing, with one sized for accessible use.
Can a Unisex Changing Room Be Used by Officials?
Yes, and it is one of the strongest arguments for building them. Sport England’s guidance notes that private changing rooms off a corridor suit officials, umpires, coaches, teachers and staff, so one room can remove the need for a separate officials room.
Does a Unisex Changing Room Need Solid Walls?
If it opens off a corridor, yes. Part D is explicit that private changing rooms accessed from circulation need traditional solid wall and door construction to the perimeter. Panel partition cubicles are for inside a larger changing room, where privacy is already partly provided by the room itself.
Get a Layout With Unisex Provision Costed
Tell us your sport, how many teams use the ground and who else is in the building midweek, and we will put a layout and a guide price together with the private rooms included.